ACCESSFLOORSTORE is a floor Resource Platform. Customer Find Small Quantity Floor Products from "LOCAL STORE" Customer Find Large Quantity Floor Products from "FACTORY ADVERTISEMENT" From Company profile and Products details. ACCESSFLOORSTORE Shares Local Store and Factory Advertisement Contact Method.
  • Home
  • News
  • 4 Popular Clean Room Floors Differences Installation And Applications How To Select The Clean Room Access Floor

4 Popular Clean Room Floors, Differences, Installation, and Applications & How to Select the Clean Room Access Floor

2019/8/28 10:29:21

With science and technology advances, the clean room, also called dust free workshop, has become an indispensable working area for electronics factory, medical, food, and other industries. The selection of clean room floors is based on product construction technique, installation and more factors. Now, Accessfloorstore.com brings you four common clean room floor panels with the difference, installation, construction, applications and choosing tips. 

clean room floor.png

Top 4 Popular Clean Room Floor Panels - Common Dust Free Floor Differences 

I. Clean Room Raised Floor

The raised access floor is suitable for electronics factory, electromechanical room, constant temperature laboratory, etc. The dust free workshop raised floor is more complicated than the PVC floor, it needs to be equipped with stringers and adjust the beam level or location.

Clean Room Raised Floor Installation

1. Draw lines on the clean ground 

2. Assemble the raised floor pedestal and stringer 

3. Adjust the stringer level and tighten the screws

4. Laying the raised floor

5. Clean the floor surface after construction is completed

Clean Room Raised Floor Applications

Electronics factory, semiconductor factory, optoelectronic industry, electromechanical room, constant temperature constant room laboratory, and 100-level purification engineering.

II. Clean Room PVC Floor

PVC floor is made of Polyvinyl chloride, which originated in Europe and now is still a popular building material in Europe and North America, it began to enter the Chinese market in the 1980s and has become the basic material for large cities in China. The construction process of this type of floor is relatively simple, just need to clean the ground and then follow the steps to install. PVC flooring is also known as lightweight flooring. 

Clean Room PVC Floor Installation

1. Clean the ground, remove the floating and sinking, and locate the laying baseline

2. Lay the copper foil and brushing conductive adhesive

3. Laying PVC floor and rolling it

4. Open 4mm static ground

Clean Room PVC Floor Applications

Electronics factory, semiconductor factory, optoelectronic industry, packaging products, mechanical and electrical room, automobile industry, etc.

III. Clean Room Epoxy Antistatic Self Leveling Floor

Epoxy resin anti-static self-leveling floor roughly has the same function as the clean room epoxy self-leveling floor, the only difference is the former one anti-static. 

Clean Room Epoxy Antistatic Self Leveling Floor Installation

1. Substrate treatment: sanding and cleaning the ground, dry and flat floor panels required 

2. Bottom coating: conductive coating

3. Laying copper foil: laying horizontally and vertically

4. Medium coating: according to the thickness of the ground, anti-static coating

5. Top coating: anti-static self-leveling flat paint

Clean Room Epoxy Antistatic Self Leveling Floor Applications

Communication equipment manufacturers, chip dust-free manufacturing plants, STM dust-free workshops, optical instruments dust-free workshops, laboratories and other dust-free workshops with high anti-static requirements.

IV. Clean Room Epoxy Self Leveling Floor

Clean room epoxy self-leveling floor has a strong automatic leveling function, you can repair the height difference of the panel so that all the exposed height of the floor can be maintained at the same level and this type of raised flooring is also very resistant to friction.

Clean Room Epoxy Self Leveling Floor Installation

1. Polish the floor, clean and vacuum

2. Brushing a closed bottom paint

3. Middle coating

4. Grinding and vacuuming

5. Self leveling

Clean Room Epoxy Self Leveling Floor Applications

Electronics factory, electrical appliance factory, food factory, cosmetics factory, packaging factory, textile factory, garment factory, etc.

How to Select the Clean Room Access Floor? 

Cleanliness Requirements

The purified production environment has become an important condition for the development of modern science and modern industry. Clean rooms can be used to ensure cleanliness, but different applications have different cleanliness requirements, some have high cleanliness requirements, such as large-scale integrated circuits, ultra-large-scale integrated circuits, etc.; some requirements are second, such as semiconductor manufacturing, gyroscopes, etc.; other cleanliness can be lower, such as electronic components, optical machines. This will also affect the clean room access floor solution.

Mechanical and Chemical Properties of Flooring

The performance of clean room flooring should be taken into consideration, including wear resistance, pressure resistance, impact resistance, acid and alkali resistance and solvent resistance. Choose the right floor that conforms to the workshop requirements. 

Floor Location and Environment

According to the floor location, underfloor or on the ground, it is necessary to determine whether moisture-proof treatment is needed or whether to select a special moisture-proof floor. The clean room raised floor also need to look harmonious with the existing environment from colors, lighting and more.

Safety Requirements

If the floor is in an oil-stained environment or on a ramp, it is necessary to choose a non-skid clean room floor.

HuiYa Accessfloorstore.com provides various clean room access floor and flooring accessories with outstanding electrostatic conductivity, high load-bearing capacity, wear and corrosion resistance and more excellent performance as well as budget price, to meet your diverse demands. 